Contents
pdf Download PDF
pdf Download XML
136 Views
5 Downloads
Share this article
Case Report | Volume 2 Issue 2 (July-Dec, 2010) | Pages 21 - 23
A case of accidental carotid artery cannulation in a patient for Hemofilter: complication and management
 ,
 ,
 ,
1
MBBS, DA Trust anaesthetist, Albans hospital West Herts NHS trust AL3 5PN
2
MBBS, FRCA, Registrar Anaesthetics, St Albans Hospital West Herts NHS Trust, Waverley Road AL3 5PN.
3
MBBS, FRCA Consultant Anaesthetics St Albans Hospital West Herts NHS Trust Waverley Road AL3 5PN
4
MBBS FRCA Consultant Anaesthetics St Albans Hospital West Herts NHS Trust. Waverley road AL3 5PN
Under a Creative Commons license
Open Access
Received
Nov. 5, 2010
Revised
Nov. 15, 2010
Accepted
Nov. 20, 2010
Published
Nov. 24, 2010
Abstract

We present a case of a 72-year-old man with acute on chronic renal failure referred for intensive care (ITU) management. History revealed dehydration and anuria for 3 days. His blood pressure was 80/40, sinus tachycardia around 130/min with cold clammy peripheries. Blood investigations revealed urea 23mmol, creatinine 800mmol, and potassium-7.7, with ECG changes of hyperkalemia. We attempted a right internal jugular (IJV) venous cannulation using landmark technique and inserted an Arrow-Howes central venous catheter with blue flexi tip, 8.5FR, 5 lumen, and 16cm length. The technique was difficult due to low blood pressure, and patient’s inability to lie flat. The ultrasound machine was unavailable at that moment. Soon after the catheter was introduced using seldinger technique, a swelling was noticed from the site of IJV cannulation. the blood sample analysis revealed arterial blood. The catheter was removed and pressure applied for 45 minutes. Thereafter, a left femoral vein catheter was inserted for central venous access and right femoral vascath –VYGON, DUALYSE Expert, 2 lumen catheters set, 12 fr, 20cm was inserted uneventfully.1 hour later the bleeding from the right carotid puncture site was examined and was found to have ceased. The patient was put on the continuous veno- venous haemofiltration (CVVHF), which clotted after 15minutes.Heparin was used as an anticoagulant for the filter. This was repeated thrice with same result. Three hours later, a haematoma was noticed in area of IJV puncture, which was gradually increasing in size.

Keywords
INTRODUCTION

Inadvertent carotid arterial puncture complication is reported to have an incidence of 2% - 8% 1, 2 and usually results in localised haematoma formation.

CASE PRESENTATION

We present a case of a 72-year-old man with acute on chronic renal failure referred for intensive care (ITU) management. History revealed dehydration and anuria for 3 days. His blood pressure was 80/40, sinus tachycardia around 130/min with cold clammy peripheries. Blood investigations revealed urea 23mmol, creatinine 800mmol, and potassium-7.7, with ECG changes of hyperkalemia.

 

We attempted a right internal jugular (IJV) venous cannulation using landmark technique and inserted an Arrow-Howes central venous catheter with blue flexi tip, 8.5FR, 5 lumen, and 16cm length. The technique was difficult due to low blood pressure, and patient’s inability to lie flat. The ultrasound machine was unavailable at that moment. Soon after the catheter was introduced using seldinger technique, a swelling was noticed from the site of IJV cannulation. the blood sample analysis revealed arterial blood. The catheter was removed and pressure applied for 45 minutes.

 

Thereafter, a left femoral vein catheter was inserted for central venous access and right femoral vascath –VYGON, DUALYSE Expert, 2 lumen catheters set, 12 fr, 20cm was inserted uneventfully.1 hour later the bleeding from the right carotid puncture site was examined and was found to have ceased. The patient was put on the continuous veno- venous haemofiltration (CVVHF), which clotted after 15minutes.Heparin was used as an anticoagulant for the filter. This was repeated thrice with same result. Three hours later, a haematoma was noticed in area of IJV puncture, which was gradually increasing in size.

 

The haematoma spread to the neck and chest after which the patient complained of discomfort with breathing difficulty. In view of increasing airway compromise the patient was transferred to theatre for elective intubation and surgical intervention. Ultrasonography by radiology consultant showed a large haematoma, but unable to see the damage in the vessel and a CT neck, thorax angiography was suggested.

 

CT angiogram revealed a leak in the bifurcation of the carotid artery. Surgical access was difficult in view of the large persistent leak. Ultrasound probe was used to make the incision superficial to the leak. A small leak was identified in the artery, which was sutured uneventfully. He was then continued on CVVHF with no further complications

DISCUSSION

Complications include arterial puncture, pneumothorax, neck or mediastinal haematoma and hemothorax3, 4. The haematoma may enlarge rapidly if the patient is coagulopathic, or if a large puncture wound is produced by the introduction of the sheath itself into the carotid artery. Airway obstruction 5, 6, pseudo aneurysm 7, 8, arterio-venous fistula formation 9 and retrograde aortic dissection 10 have all been reported as a consequence of carotid puncture. In the presence of occlusive (atheromatous) carotid disease, inadvertent puncture may carry the risk of precipitating a cerebrovascular accident 11.

 

NICE guidelines 2002 recommended use of ultrasound for central venous cannulation12. The Royal College of Radiology

 

(RCOR) recommends practical training in vascular ultrasound should involve at least two ultrasound lists per week over less than three months up to 6 months. Meta-analysis including 18 Randomized Controlled Trials by NICE concluded that ultrasonographic (USG) venous catheterization was more effective than landmark technique for all outcomes 13. Royal College of Anaesthetists feels guidance is fair and sensible but landmark technique is still acceptable alternative whether 2D available or not.

CONCLUSION

Complications following central venous cannulation are reduced if the procedure is USG guided and therefore must be used whenever possible. But landmark technique is still an acceptable alternative.

 

Competing Interests: None Declared

REFERENCES
  1. Davies, M. J., Cronin, K. D., and Domaingue, C. M. "Pulmonary Artery Catheterization: An Assessment of Risks and Benefits in 220 Surgical Patients." Anaesthesia and Intensive Care, vol. 10, no. 9, 1982. DOI: 10.1177/0310057X8201000905.
  2. Patel, C., Laboy, V., Venus, B., Mathru, M., and Wier, D. "Acute Complications of Pulmonary Artery Catheter Insertion in Critically Ill Patients." Critical Care Medicine, vol. 14, no. 3, Mar. 1986, pp. 195-197. DOI: 10.1097/00003246-198603000-00007.
  3. Abbound, P., and Kendall, J. "Ultrasound Guidance for Vascular Access." Emergency Medicine Clinics of North America, vol. 22, 2004, pp. 749-773. DOI: 10.1016/j.emc.2004.06.007.
  4. Randolf, A. G., Cook, D. J., Gonzales, C. A., et al. "Ultrasound Guidance for Placement of Central Venous Catheters: A Meta-Analysis of the Literature." Critical Care Medicine, vol. 24, 1996, pp. 2053-2058. DOI: 10.1097/00003246-199612000-00003.
  5. Knoblanche, G. E. "Respiratory Obstruction Due to Haematoma Following Internal Jugular Vein Cannulation." Anaesthesia and Intensive Care, vol. 7, no. 3, 1979, pp. 286-288. DOI: 10.1177/0310057X7900700310.
  6. Kua, J. S., and Tan, I. K. "Airway Obstruction Following Internal Jugular Vein Cannulation." Anaesthesia, vol. 52, 1997, pp. 776-780. DOI: 10.1111/j.1365-2044.1997.139079.x.
  7. Shield, C. F., Richardson, J. D., Buckley, C. J., et al. "Pseudoaneurysm of the Brachiocephalic Arteries: A Complication of Percutaneous Internal Jugular Vein Catheterization." Surgery, vol. 78, 1975, pp. 190-193. DOI: 10.1016/S0039-6060(75)80197-0.
  8. Aoki, H., Mizobe, T., Nozuchi, S., et al. "Vertebral Artery Pseudoaneurysm: A Rare Complication of Internal Jugular Vein Catheterization." Anesthesia & Analgesia, vol. 75, 1992, pp. 296-298. DOI: 10.1213/00000539-199209000-00007.
  9. Gobeil, F., Couture, P., Girard, D., and Plante, R. "Carotid Artery-Internal Jugular Fistula: Another Complication Following Pulmonary Artery Catheterization via the Internal Jugular Venous Route." Anesthesiology, vol. 80, 1994, pp. 23-232. DOI: 10.1097/00000542-199401000-00011.
  10. Applebaum, R. M., Adelman, M. A., Kanschuger, M. S., Jacobowitz, G., and Kronzon, I. "Transesophageal Echocardiographic Identification of a Retrograde Dissection of the Ascending Aorta Caused by Inadvertent Cannulation of the Common Carotid Artery." Journal of the American Society of Echocardiography, vol. 10, no. 7, Sep. 1997, pp. 749-751. DOI: 10.1016/S0894-7317(97)70031-3.
  11. Zaidi, N. A., Khan, M., Naqvi, H. I., and Kamal, R. S. "Cerebral Infarct Following Central Venous Cannulation." Anaesthesia, vol. 53, 1998, pp. 186-191. DOI: 10.1111/j.1365-2044.1998.00794.x.
  12. NICE Guidelines on Use of Ultrasound Devices for Placing Central Venous Catheters. Technology Appraisal Guidance No. 49, September 2002. DOI: 10.1111/j.1365-2044.1998.00794.x.
  13. Hind, D., Calvert, N., McWilliams, R., et al. "Ultrasound Locating Devices for Central Venous Cannulation: Meta-Analysis." BMJ, vol. 326, 2003, pp. 361-367. DOI: 10.1136/bmj.326.7383.361.
Recommended Articles
Research Article
Exploring the Link Between BMI and Blood Sugar Regulation in Type 2 Diabetes Mellitus
Published: 06/06/2022
Research Article
A Study on Treatment of Major Depressive Psychosis in a Tertiary Care Hospital in Bangalore, India
Published: 29/12/2018
Research Article
Risk Factors for Obstructive Sleep Apnea: A Cross-Sectional Study in Adults Visiting ENT Clinics
Published: 29/12/2020
Research Article
A Clinical Study on the Management of Anxiety Disorders in a Tertiary Care Hospital in Andhra Pradesh, India
Published: 21/01/2020
Chat on WhatsApp
© Copyright CME Journal Geriatric Medicine